| Technical data: |
PUE C/31H |
PUE C/31H/Z |
| Display |
LCD |
| Keyboard |
microswitch |
| Quantity of buttons |
5 |
| Maximal quantity of verifying units |
6000 e |
| Maximal quantity of countings from A/C converter |
838 860 × 10 |
| Maximal increase of signal |
19,2 mV |
| Maximal voltage on one verifying unit |
3,2µV |
| Minimal voltage on one verifying unit |
1,0µV |
| Working temperature |
-10° - +40 °C |
| Minimal impedance of load cell |
80  |
| Maximal impedance of load cell |
1200  |
| Connection of load cells |
4 or 6 cables + shield |
| Multi range |
1 or 2 ranges |
| Voltage on load cell |
5V DC |
| Interface |
RS 232 |
| Aditional display |
LCD (option) |
| Casing |
stainless steel |
| IP rating |
IP 66/67 |
| Standard power supply |
110-120VAC 60Hz and
220-240VAC 50Hz and
SLA 6V/3,4Ah |
power adapter 230V AC/11VAC
and SLA 6V/3,4Ah |
| Optional power supply |
- |
10-12V AC/1,1A Imax=600mA |
| Means of power supply |
power supply cable built in SLA battery |
detachable adapter for charging
battery built in SLA battery |
| Average active time on accumulators |
45 h |